Friday, May 11, 2018

Re: [MW:27833] Hydro test with Normal Water

Hi Mohanraj,

Normally potable water is/ may be used/allowed for hydrotest for CS (SA 106 Grades) and LAS material like P11, P22, etc. However please check with client and their specific requirement for quality of water.

Thanks,
Warm Regards,

Rajnish Dixit
Lead - QA-QC/QMS/Welding/NDT/Inspection
+91 972 4200 357

On Fri, May 11, 2018 at 10:06, Mohan
<ggnanamalli@gmail.com> wrote:
Dear Experts,

We are installing HRSG (Heat Recovery Steam Generator) consist of Alloy Steel (P11, P22) and Carbon steel SA106 Gr.B tube bundles.

 In our past experience we did hydro test with demineralized water (DM) but in current project there is scarcity in procuring of DM water can we proceed with Hydro test with Normal RO water.

IF not water are major consequences to tube bundles.

Regards
G.Mohanraj

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone