Your interpretation is not right.
On Thu, 24 May 2018, 15:41 Aakash, <harenathjha@gmail.com> wrote:
--Hello All,I was going through the ASME section IX-2017 edition QW-424, Please see the circled part,My interpretation is , if we are welding(PQR) between P-1 to P-22, and qualify the procedure , then my PQR is qualified for P-1 to P-1 and P-22 to P-22 also.Please let me know that my interpretation is correct or not ?RegardsAAkash