Dear Aly ;
There is no problem to change ( we have the same classification and specification according ASME sect. IX).
Regards
SALHI Raouf
QA/QC Engineer
Tel: Morocco +212628979891
Tunisia +21621458258
Le Mercredi 15 avril 2015 15h18, Mhaskar Aly <mhaskar.aly@gmail.com> a écrit :
Dear All,
We have PQR of following details:
Process SAW with Filler Wire EM12K (ESAB) with Flux F7A8 (ESAB OK 10.62 Flux)
Question:
1. Can we use Filler Wire EM12K (Bohler) with Flux F7A8 (ESAB OK 10.62 Flux)
2. Can we use Filler Wire EM12K (Bohler) with Flux F7A8 (Bohler Flux)
Kindly advise as per ASME Sec IX…with reference.
Thanks in advance
Ali Mhaskar,
QA/QC Manager
Velath Engineering International FZC; Hamriyah FreeZone Sharjah, UAE; * P.O Box 6268 – Sharjah UAE.
(Phone: 00971-6-526 9269, 526 9185, 526 9119 Ext-212 ÈMobile no.: 00971-55 265 3598 ÊFax no. 00971-6-526 9393 üwww.velath.com
(Phone: 00971-6-526 9269, 526 9185, 526 9119 Ext-212 ÈMobile no.: 00971-55 265 3598 ÊFax no. 00971-6-526 9393 üwww.velath.com
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAOenW4htWh-B5O0xAn_yPAbYpWWRcX6NWmDT5tmmziG3jgPAxQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
No comments: