Dear Sir,
We used ferrite meter equipment.
Pravin Poornachandran
Which test did you implement for measuring the ferrite content?Ferrite meter equipment or metallography?--On Wed, Apr 15, 2015 at 5:39 AM, Pravin G <htcispravin@gmail.com> wrote:Dear expert,
I'm having to weld normal duplex plate for vessel, SMAW process with following requirements:
I.v -40degC
FN: 35-65
CPT 22deg C @24 hrs
Corrosion 4g/mm
I'm unable to achieve FN even after several test.
Can anyone guide me how to achieve FN ?
Pravin
Singapore
Sent from my iPhone
--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/C06614E3-D0AA-42F0-9BA6-9A63A4690B7C%40gmail.com.
For more options, visit https://groups.google.com/d/optout.
--M. Shokri ArfaeiISA-ISTS - Metallurgy Lab. ManagerASNT NDT Level IIIInternational Welding EngineerTel.: +98 21 66282127Fax: +98 21 66282779Mob.:+98 912 1394023
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAC8uMts043CrnjNht6Km%2BQy7MLfjSE-FhtVUJsz6-4%3Dbxq3oXg%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.