[MW:8012] RT of longitudinal seam

Dear Friends,
 
 Having doubt ,when longitudinal seam an intersecting with circuferential seam,Taking RT of circumferential full girth 100%, is acceptable or have to take 38mm of longitudinal seam  an intersecting point and reference is B31.3 cl341.4.1

The welds to be examined shall be selected to

ensure that the work product of each welder or welding

operator doing the productionwelding is included. They

shall also be selected to maximize coverage of intersections

with longitudinal joints. When a circumferential

weld with an intersecting longitudinal weld(s) is examined,

at least the adjacent 38 mm (1

12 in.) of each intersecting

weld shall be examined.

 

thanks and regards

Sujay

--