Friday, August 27, 2010

Re: [MW:6739] acceptance criteria of DPT

It's related to your specifications or code which you used for example if you work in power station, the used code is B31.1-2007 and you shall refer to 136.4.4 for the DPT acceptance criteria
Otherwise some cases order you to use the specifications of the client which has special acceptance criteria 


From: aslam khan <aslamkhan4u@gmail.com>
To: materials-welding@googlegroups.com
Sent: Thu, August 26, 2010 8:32:42 PM
Subject: [MW:6736] acceptance criteria of DPT

HI FRIENDS,
CAN ANY BODY TELL ME ABOUT THE ACCEPTANCE CRITERIA OF DPT ?ACCEPTANCE RANGES OF DEFECTS LIKE UNDERCUT,PORE,POROSITY,CRACK,etc.thanks
 
Regards
M.Aslam Khan
QA/QC ENGINEER

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...