Hi, Acceptance criteria for defect depend on standard,code or spec. in project such as ASME, AWS, BSI, GL, BV,... . ASME : Undercut, LOF, LOP, Crack = 0. AWS: Undercut in static condition=0.8 mm, dynamic condition=0. LOF and LOP=0.
--- On Thu, 8/26/10, aslam khan <aslamkhan4u@gmail.com> wrote:
From: aslam khan <aslamkhan4u@gmail.com> Subject: [MW:6736] acceptance criteria of DPT To: materials-welding@googlegroups.com Date: Thursday, August 26, 2010, 10:32 AM
HI FRIENDS, CAN ANY BODY TELL ME ABOUT THE ACCEPTANCE CRITERIA OF DPT ?ACCEPTANCE RANGES OF DEFECTS LIKE UNDERCUT,PORE,POROSITY,CRACK,etc.thanks Regards M.Aslam Khan QA/QC ENGINEER -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
|
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.