Re: [MW:5326] Peaking & Bending Measurement of Welded Joints in Cylindrical Storage Tanks....

Please,refer to API 650 Eleventh Edition, Addendum 2008, Numeral 7.5.2 Plumbness, 7.5.3 Roundness and 7.5.4 Local Deviations. All are very importand mesurement. Regards, jml 2010/5/31 jose seban < joseseban@gmail.com > Dear Friends, I am making fixed roof cylindrical oil storage tanks as per Indian Standards IS-803.In section 9.3.5 it is mentioned about circularity and shape.There it is mentioned about verticality & circularity tolerences.Also it is mentioned about peaking and bending of welds there.. 1.Peaking of vertical weld joints measured over an arc length of 1 m shall not exceed 12 mmm. 2.Bending of horizontal weld joints measured by a straightedge of 1 m length shall not exceed 12 mm. My questions are.. 1.What is meant by this peaking and bending there? 2.How we will measure these factors? 3.How would the unit "millimetre" will come for these factors measurement? 4.Is these 2 measurements are important in tank fabrication,if I am checking vericality ...

Re: [MW:5325] silicon content

Mr Soliman is correct, I misread the part on the chemical analysis table   On Sun, May 30, 2010 at 8:07 AM, mero soliman < meroman_one@hotmail.com > wrote: Dear all. i have checked the SA 106, and i found no limitation in Si%, but, by experience, in most material test reports i have ever checked, the Si content is (0.2-0.35%) for the carbon steel SA106-B pipes. - i recommend using the IIW equation in evaluationg the carbon EQUIVALENT, not the API 577 RP Formula, Because the second formula is written as for an example ( i.e : NOT MANDATORY). Amr Soliman QA/QC Eng. petrojet-Egypt Hotmail: Trusted email with powerful SPAM protection. Sign up now. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views...

Re: [MW:5324] Peaking & Bending Measurement of Welded Joints in Cylindrical Storage Tanks....

Mr.Jose,              Reply to your questions are as follows,   1.Peaking & banding  is nothing but the profile of the tank i.e while erecting the shell plates the curvature to be maintained. The shell plates rolled to a radius to be maintained till the welding of joints completed.For this purpose only the curavture of joints are checked. For vertical joints of tank curvature is called as Peaking. For Horizontal joints it is called a Banding.Banding is also called a straightness. 2.These can be measured by making a template of 1 mtrs length.Template shall be of a  wooden board .Mark the radius of the tank shell in an wooden board and cut accordingly.One side of the template shall be used for peaking and the other side straight side shall be used for banding.There is no specific requirement for making a template just make for easy handling 3.Keep the template-straight side on the centre of horizontal joints so now you will find half(500mm)on one shell course and remaining h...

RE: [MW:5322] unequal thickness in UCS66

Pl refer para UCS 66, which gives the creteria for governing thickness of varous components in a vessel, including disimilar thick joints, such as nozzle to shell, with ref to figures given elsewhere in this section. If you need more info can provide your joint configuration. Sent from my Nokia phone -----Original Message----- From: Ali Asghari Sent: 31/05/2010 6:01:26 pm Subject: [MW:5319] unequal thickness in UCS66 Dear All according ASME secVIII(DIV1), what is governing thickness in unequal base metals' thickness of a weld joint for impact test?(if tapered or not) regards -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own de...

RE: [MW:5321] Peaking & Bending Measurement of Welded Joints in Cylindrical Storage Tanks....

You can make a template from a steel sheet / scrap plate with radius of template equal to your tank radious with an arc length of aprx 1 mtr. place this on your tank and if you are getting greater than 12mm gap, needs rectification. Similar way use 1 mtr steel rule as straight edge to check verticality. Your 4th point itself is an answer to your query. How do you intended to check verticality and circularity? Sent from my Nokia phone -----Original Message----- From: jose seban Sent: 31/05/2010 6:40:27 pm Subject: [MW:5320] Peaking & Bending Measurement of Welded Joints in Cylindrical Storage Tanks.... Dear Friends, I am making fixed roof cylindrical oil storage tanks as per Indian Standards IS-803.In section 9.3.5 it is mentioned about circularity and shape.There it is mentioned about verticality & circularity tolerences.Also it is mentioned about peaking and bending of welds there.. 1.Peaking of vertical weld joints measured over an arc length of 1 m shall not exceed 12 mmm...

Re: [MW:5323] Electrode for SA516 Gr.70 Material.

Dear All, Can we use E7018-G electrode?? Regards, Vijay On Mon, May 31, 2010 at 9:06 AM, KOLA Ramalingeswara Rao < krraoind@gmail.com > wrote: As per ASME Sec II part C, E7018 electrode impact test up to minus 30 degrees C. You can use E7018-1 for  minus 46 degree C.   Regards,   K.Ramalingeshwara rao. On Sun, May 30, 2010 at 9:17 PM, Vijay < k.vijayaraj@gmail.com > wrote: Dear All, Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at -46 oC) or we need to use other?? Kindly clarify. Regards, Vijay, Advanced Oilfield Technology Company, Oman. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decis...

[MW:5320] Peaking & Bending Measurement of Welded Joints in Cylindrical Storage Tanks....

Dear Friends, I am making fixed roof cylindrical oil storage tanks as per Indian Standards IS-803.In section 9.3.5 it is mentioned about circularity and shape.There it is mentioned about verticality & circularity tolerences.Also it is mentioned about peaking and bending of welds there.. 1.Peaking of vertical weld joints measured over an arc length of 1 m shall not exceed 12 mmm. 2.Bending of horizontal weld joints measured by a straightedge of 1 m length shall not exceed 12 mm. My questions are.. 1.What is meant by this peaking and bending there? 2.How we will measure these factors? 3.How would the unit "millimetre" will come for these factors measurement? 4.Is these 2 measurements are important in tank fabrication,if I am checking vericality & circularity properly? Regards, Jose Sebastian, Quality Manager, Adani Power Limited, Gujrat,India. Mob:+919687660525 -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, sen...

[MW:5318] IQI set selection

Dear All My job is Carbon steel and thickness is 20 mm. For radiography I have to select the IQI set as material group as “1” and wire type set as “A or B or C or D”. Can you please guide me how to select the set identification number based on thickness of job.   Thanks in advance  

Re: [MW:5317] Expiry date

Dear Sandeep, As electrode manufacturer we recommend maximum 3 years storage under recommended conditions. If you redry them according to the manufacturers recommendation, they will be returned to mint condition. This is sound engineering practice. If the electrodes are packed in an air tight package, they can technically be stored for a very long time. However, there is a limit to how long time documentation is kept by the manufacturer, normally not more than 10 years. Best regards, Claes Gillenius Sandeep Kp <sandeepkp99@yahoo.com> Sent by: materials-welding@googlegroups.com 2010-05-31 04:20 Please respond to materials-welding@googlegroups.com To materials-welding@googlegroups.com cc Subject [MW:5300] Expiry date Dear all, How many year we can keep E7018 electrode in recomended temperature.   With Regards,     sandeep.k.p -- To post to this group, send email to materials-welding@googlegroups.com To unsubscr...

Re: [MW:5316] DP test Requirement in Overlay PQR.

Dear Rao, Client is correct, if job is requires PWHT, NDT shall be perforemd after PWHT.   Regards,   K.Ramalingeshwara Rao. On Sat, May 29, 2010 at 1:12 PM, PAMULA < vasantharao2009@rediffmail.com > wrote: Dear All, I have conducted Overlay PQR qulification (316L OVERLAY ON SA516 Gr.70N) as per ASME Sec IX. As per ASME SEC IX QW-453, note 4, 5, 9, we have conducted 1. DP test after every layer(total 3layers) in as-welded condition. 2. 4-Side bend tests in PWHT condition. 3. Chemical analysis from overlay specimen in as-welded condition. Job requirement: 316L weld overlay on SA516 Gr.70, vessel will under PWHT at 620 Deg.C. ASME Div.1 Cladded Vessel. Client Comments on PQR. client is demanding us to provide DP report After PWHT of the overlay. Client says PWHT is essential variable, DP test & bend tests should be conducted after PWHT. Query. Is it Code (Sec.IX or Div.1 ) requirement to conduct DP test after PWHT ?. If it is code requirement, pl. provide the referen...

Re: [MW:5315] Electrode for SA516 Gr.70 Material.

As per ASME Sec II part C, E7018 electrode impact test up to minus 30 degrees C. You can use E7018-1 for  minus 46 degree C.   Regards,   K.Ramalingeshwara rao. On Sun, May 30, 2010 at 9:17 PM, Vijay < k.vijayaraj@gmail.com > wrote: Dear All, Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at -46 oC) or we need to use other?? Kindly clarify. Regards, Vijay, Advanced Oilfield Technology Company, Oman. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from ...

Re: [MW:5314] Electrode for SA516 Gr.70 Material.

Hi Vijay, According to ASME Sec-II Part-C 2007 ed, SFA-5.1 , Table 3 ( Charpy Impact requirement),E7018 testing requirement at -30 deg C &  E7018-1 testing requirement at -45 deg C, if your requirement is at -46 deg C, then it will not be suitable.   Regards,  On Mon, May 31, 2010 at 10:56 AM, raghurambathula@gmail.com < raghurambathula@gmail.com > wrote: You can use E7018-1, however if your service is non corrossive (non NACE or no restriction on Ni %), E 7018-C3L, 8016-C1 could be a betterchoice. Sent from my Nokia phone -----Original Message----- From: Vijay Sent:  30/05/2010 11:47:20 pm Subject:  [MW:5303] Electrode for SA516 Gr.70 Material. Dear All, Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at -46 oC) or we need to use other?? Kindly clarify. Regards, Vijay, Advanced Oilfield Technology Company, Oman. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials...

Re: [MW:5313] Expiry date

Heloo,   it is all depends on manufacturer specification.Genarally 2 mansoons for valid.1 year   On 5/30/10, Sandeep Kp < sandeepkp99@yahoo.com > wrote: Dear all, How many year we can keep E7018 electrode in recomended temperature.   With Regards,     sandeep.k.p   -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- Thanks  & Best Regards, Suresh Mobile No: 91-92 92 905 905 -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more optio...

RE: [MW:5306] Electrode for SA516 Gr.70 Material.

You can use E7018-1, however if your service is non corrossive (non NACE or no restriction on Ni %), E 7018-C3L, 8016-C1 could be a betterchoice. Sent from my Nokia phone -----Original Message----- From: Vijay Sent: 30/05/2010 11:47:20 pm Subject: [MW:5303] Electrode for SA516 Gr.70 Material. Dear All, Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at -46 oC) or we need to use other?? Kindly clarify. Regards, Vijay, Advanced Oilfield Technology Company, Oman. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- To post to this group, send email to materials-welding...

Re: [MW:5312] DIN Wire IQI Thickness

Hi Refer ASTM E747 for IQI radiography. Regards Manpreet Singh Welding Engineer Spiecapag On Sun, 30 May 2010 14:10:38 +0530 wrote >Dear All Where to we find DIN wire IQI Thickness? Which standard is deals about DIN wire IQI Thickness? Where to refer? -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot...

Re: [MW:5311] FLANGE RATING 10000#

Hi Mero. Is a flange 12" rating 10000# welding neck and Ring Joint, is welded in un pipe API 5L Gr. X60 of 2.65" thickness.   Agustin  De: mero soliman <meroman_one@hotmail.com> Para: materials-welding@googlegroups.com Enviado: dom, mayo 30, 2010 9:51:18 AM Asunto: RE: [MW:5299] FLANGE RATING 10000# dear augsten please mention the rest of the marking Date: Wed, 26 May 2010 18:32:02 +0400 Subject: Re: [MW:5259] FLANGE RATING 10000# From: vipingeorges@gmail.com To: materials-welding@googlegroups.com Dear Agustin, Standard API 6A for rating over 10,000 Regards, Vipin On Wed, May 26, 2010 at 5:37 AM, AGUSTIN JIMENEZ < agumarca@yahoo.com > wrote: Hello everybody. I need know over rating 10000# flange Fabrication standart? wich is?   Best Regars Agustin Jimenez   -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroup...

Re: [MW:5310] Re: DP test Requirement in Overlay PQR.

Irrespective of  yr PQR, code req etc Penetrant testing (PT) has a meaning and purpose if it is done after SR and final machining. This does not preclude testing at different stages of manufacture (i.e) interstage ,PT after complete welding and machining prior to HT. Regds MSR On Sun, May 30, 2010 at 8:53 PM, sandeep p < sandeep1dxb@gmail.com > wrote: Dear Rao, No doubts about the client requirement,b'coz always NDT can done after PWHT. Thanks, Sandeep.k.p On May 29, 2:12 pm, "PAMULA " < vasantharao2...@rediffmail.com > wrote: > Dear All, > > I have conducted Overlay PQR qulification (316L OVERLAY ON SA516 Gr.70N) as per ASME Sec IX. > > As per ASME SEC IX QW-453, note 4, 5, 9, we have conducted > > 1. DP test after every layer(total 3layers) in as-welded condition. > 2. 4-Side bend tests in PWHT condition.   > 3. Chemical analysis from overlay specimen in as-welded condition. > > Job requirement: ...

Re: [MW:5308] Electrode for SA516 Gr.70 Material.

Dear Mr. Vijay,   You should use E 7018-1 electrode which give imapct at -50 C where as the E 7018 is gauranted for -29 C only.   Regards   N.V. PRASAD WELDING ENGINEER, VELOSI CERTIFICATION, QATAR. 00974 5974703 On Sun, May 30, 2010 at 9:17 PM, Vijay < k.vijayaraj@gmail.com > wrote: Dear All, Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at -46 oC) or we need to use other?? Kindly clarify. Regards, Vijay, Advanced Oilfield Technology Company, Oman. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- To post to this group, send email to m...

Re: [MW:5309] DP test Requirement in Overlay PQR.

Dear Mr. Rao As per ASME sec viii div 1,No 42 , VIII-1-98-09,NDT can be performed before PWHT as well. in my opinion, Doing a DP test is not a big deal,if client asking for it,you should fulfill his requirements. Regards Manpreet Singh Welding Engineer Spiecapag On Sun, 30 May 2010 12:34:57 +0530 wrote > > > Dear All, > > I have conducted Overlay PQR qulification (316L OVERLAY ON SA516 Gr.70N) as per ASME Sec IX. > > As per ASME SEC IX QW-453, note 4, 5, 9, we have conducted > > 1. DP test after every layer(total 3layers) in as-welded condition. > 2. 4-Side bend tests in PWHT condition. > 3. Chemical analysis from overlay specimen in as-welded condition. > > Job requirement: > 316L weld overlay on SA516 Gr.70, vessel will under PWHT at 620 Deg.C. > ASME Div.1 Cladded Vessel. > > Client Comments on PQR. > > client is demanding us to provide DP report After PWHT of the overlay. ...

Re: [MW:5307] DIN Wire IQI Thickness

Please see the attached file for the IQI details. Please refer the table in attached file for the relation between different code set and wire number. Please fill free to contact if any more details required. Regards, Bhaskar kale On Sun, May 30, 2010 at 9:55 PM, AGUSTIN JIMENEZ < agumarca@yahoo.com > wrote: Hi Srinivas. You can revised in ASME Section 5 Article 2 / T-233 Image Quality Indicator (IQI) Design, API 1104 / 11.1.5 Selection of Image Quality Indicators (IQI), ASTM E 747 or ISO 1027 too. I hope that it information was utility.   Best regards. Agustin Jimenez De: Srinivas Engr < srinivas.gmsrini@gmail.com > Para: Materials & Welding < materials-welding@googlegroups.com > Enviado: dom, mayo 30, 2010 2:20:00 AM Asunto: [MW:5292] DIN Wire IQI Thickness Dear All Where to we find DIN wire IQI Thickness? Which standard is deals about DIN wire IQI Thickness? Where to refer? -- To post to this group, send email to materials-welding@goog...

[MW:5305] ask about comparison table material GB ( chinesse ) to ASME

Hello, my name Dean....i'm new member of this group. Right now i'm doing some boiler project using material from chinesse. Can someone help me with the information about chinesse material in boiler, especially about the material comparison table to ASME. thanks for the attention before -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

RE: FW: [MW:5304] group of SA517

Dear Ali,   I have attached a comprehensive guideline from ISG (Now Arcelor) for your reference. You need to work out a full fabrication (including forming) and welding/PWHT guidelines  so as to handle Q&T steels successfully.    Typically SA 517  grade steels would require some degree (100-150 deg C max) of preheating for successful thermal cutting depending on the thickness.Following cutting the kerf and cutting burrs shall be smoothly ground to remove all serrations. LPI or MPI shall be done on all cut weld bevels.   While forming the dished heads, some form of warm forming typically below the  code recommended PWHT temperature would always be advisable. If  forming method is hot forming them heads should  preferably be subject to Q&T operations again. You may need to contact and discuss this aspect with the steel mill, before proceeding with forming and other fabrication aspects.   Typicall...

[MW:5303] Electrode for SA516 Gr.70 Material.

Dear All, Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at -46 oC) or we need to use other?? Kindly clarify. Regards, Vijay, Advanced Oilfield Technology Company, Oman. -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Re: [MW:5302] DIN Wire IQI Thickness

Dear srinivas, refer ASME section V table 276 for sizes   puneet takiar ________________________________ ----- Original Message ---- From: Srinivas Engr < srinivas.gmsrini@gmail.com > To: Materials & Welding < materials-welding@googlegroups.com > Sent: Sat, 29 May, 2010 6:50:00 PM Subject: [MW:5292] DIN Wire IQI Thickness Dear All Where to we find DIN wire IQI Thickness? Which standard is deals about DIN wire IQI Thickness? Where to refer? -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- To post to this group, send email to materials-welding@googlegroups.com ...

[MW:5301] Re: DP test Requirement in Overlay PQR.

Dear Rao, No doubts about the client requirement,b'coz always NDT can done after PWHT. Thanks, Sandeep.k.p On May 29, 2:12 pm, "PAMULA " < vasantharao2...@rediffmail.com > wrote: > Dear All, > > I have conducted Overlay PQR qulification (316L OVERLAY ON SA516 Gr.70N) as per ASME Sec IX. > > As per ASME SEC IX QW-453, note 4, 5, 9, we have conducted > > 1. DP test after every layer(total 3layers) in as-welded condition. > 2. 4-Side bend tests in PWHT condition.   > 3. Chemical analysis from overlay specimen in as-welded condition. > > Job requirement: > 316L weld overlay on SA516 Gr.70, vessel will under PWHT at 620 Deg.C. > ASME Div.1 Cladded Vessel. > > Client Comments on PQR. > > client is demanding us to provide DP report After PWHT of the overlay. > > Client says PWHT is essential variable,  DP test & bend tests should be conducted after PWHT. > > Query. > > Is it Code (Sec.IX...

RE: [MW:5299] FLANGE RATING 10000#

dear augsten please mention the rest of the marking Date: Wed, 26 May 2010 18:32:02 +0400 Subject: Re: [MW:5259] FLANGE RATING 10000# From: vipingeorges@gmail.com To: materials-welding@googlegroups.com Dear Agustin, Standard API 6A for rating over 10,000 Regards, Vipin On Wed, May 26, 2010 at 5:37 AM, AGUSTIN JIMENEZ < agumarca@yahoo.com > wrote: Hello everybody. I need know over rating 10000# flange Fabrication standart? wich is?   Best Regars Agustin Jimenez   -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. -- To post to this group, send e...

RE: [MW:5298] silicon content

Dear all. i have checked the SA 106, and i found no limitation in Si%, but, by experience, in most material test reports i have ever checked, the Si content is (0.2-0.35%) for the carbon steel SA106-B pipes. - i recommend using the IIW equation in evaluationg the carbon EQUIVALENT, not the API 577 RP Formula, Because the second formula is written as for an example ( i.e : NOT MANDATORY). Amr Soliman QA/QC Eng. petrojet-Egypt Hotmail: Trusted email with powerful SPAM protection. Sign up now.

Re: [MW:5297] DIN Wire IQI Thickness

Hi Srinivas. You can revised in ASME Section 5 Article 2 / T-233 Image Quality Indicator (IQI) Design, API 1104 / 11.1.5 Selection of Image Quality Indicators (IQI), ASTM E 747 or ISO 1027 too. I hope that it information was utility.   Best regards. Agustin Jimenez De: Srinivas Engr <srinivas.gmsrini@gmail.com> Para: Materials & Welding <materials-welding@googlegroups.com> Enviado: dom, mayo 30, 2010 2:20:00 AM Asunto: [MW:5292] DIN Wire IQI Thickness Dear All Where to we find DIN wire IQI Thickness? Which standard is deals about DIN wire IQI Thickness? Where to refer? -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own dec...

Re: [MW:5296] DIN Wire IQI Thickness

I am not sure, but please try EN 462-1. With Regads, Rutvik Sr.Surveyor TATA Projects Ltd. --- On Sun, 30/5/10, Srinivas Engr < srinivas.gmsrini@gmail.com > wrote: > From: Srinivas Engr < srinivas.gmsrini@gmail.com > > Subject: [MW:5292] DIN Wire IQI Thickness > To: "Materials & Welding" < materials-welding@googlegroups.com > > Date: Sunday, 30 May, 2010, 12:20 PM > Dear All > > Where to we find DIN wire IQI Thickness? > Which standard is deals about DIN wire IQI Thickness? > Where to refer? > > -- > To post to this group, send email to materials-welding@googlegroups.com > To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com > For more options, visit this group's bolg at http://materials-welding.blogspot.com/ > The views expressed/exchnaged in this group are members > personel views and meant for educational purposes only, > Users must take their own decisions ...

[MW:5295] RE: 5292] DIN Wire IQI Thickness

Hi dear You can find your requirements in DIN EN 462(1,2,3,4,5,6) Best regards -----Original Message----- From: materials-welding@googlegroups.com [mailto: materials-welding@googlegroups.com ] On Behalf Of Srinivas Engr Sent: Sunday, May 30, 2010 11:20 AM To: Materials & Welding Subject: [MW:5292] DIN Wire IQI Thickness Dear All Where to we find DIN wire IQI Thickness? Which standard is deals about DIN wire IQI Thickness? Where to refer? -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents. __________ Information from ESET NOD32 Antivirus, version of virus signature database 5155 (20100...

Re: [MW:5294] DIN Wire IQI Thickness

Wire IQI Used to assess sensitivity ; quality of technique  Pl refer DIN 54109 (1962); ISO 1027 Wire set 1-7; set 6-12; set 10-16 ( 1,7,6,12,10,16 represent wire numbers) 3 sets - each set having 7 wires (overlapping with adj set) arranged in GP usually 2% or lesser value of sensitivity is required for general applications Smaller no 1% indicates higher sensitivity -critical applications wire dia           wire No    mm                            3.2 ...............  1     2.5   ...............  2    2.0   ...............  3    1.6   ...............4    1.25 ............... 5    1.0   ............... 6     0.8   ............... 7 ---------------------------          1.0    .............. 6     0.8   ............... 7        0.63 ...............8     0.50................9     0.40..............10      0.32..............11     0.25...............12 -----------------------------      0.40..............10     0.32..............11     0.25..............12     0.20  ......