Wednesday, March 31, 2010

[MW:4648] Multiple PQRs for Impact test requirement

 
Hi Members,
 
Please provide a solution for the following issue.
 
Shell Material : SA 516 Gr.70 -- 50 mm Thk
Nozzle : SA 333 Gr.6 --- 7 mm thk
 
MDMT : - 46 Deg.C
 
I need to weld the nozzle to shell. I have a PQR with SMAW process qualified in 40 mm thk and another PQR with SMAW qualified in 6 mm thk.
 
As per Sec. IX if impact test is required the 40 mm PQR will support from 16 mm to 200 mm. base metal Thk. and the other PQR will support from 6 mm to 12 mm thk.
 
If I club these PQR can I write a WPS to support 6 mm to 200 mm?.
Is there any issue for the missing range of qualification between 12 mm to 16 mm?.
Or is it required to add another PQR to fill the missing thickness range from 12 to 16 mm between the first two PQRs?.
Or can I write a WPS directly with range 5mm to 200mm omiting impact test requirement for this joint as it is a category D joint and excempted from Production Test Coupon?.

Thanks & Regards
Muhammed Ibrahim PK

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone