[MW:4603] Code limit of porosity and penetration as per SEC. IX of ASME

Dear All
Good Day
 
What is the code limit (Only Visual Examination) of Porosity and Root Penetration as per SEC. IX of ASME on 6"dia Sch 80(10.97mm thk) pipe Welded by SMAW Process in 6G position(Welder Performance Qualification).
 
As per QW-194 Performance test coupons shall show complete joint penetration with complete fusion of weld metal and base metal.....
 
Kindly Clarify and give ur views on this...
 
RGDS
M.R.Gupta
9820604076


The INTERNET now has a personality. YOURS! See your Yahoo! Homepage.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
To unsubscribe from this group, send email to materials-welding+unsubscribegooglegroups.com or reply to this email with the words "REMOVE ME" as the subject.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...