Hello all,
Does anyone has a experience of using A193 B8 Cl. 2 bolting for ASME B16.5 flange assembly for temperature range of -29 to 450 deg C and pressure class 150 & 300 ?
Please guide me any specific limitations for its application ?
Also few specific concerns are :
1) A193 code has a note stating "Austenitic steels in the strain hardened condition may not show uniform properties throughout the section particularly in sizes over 3/4 in in diameter ". But Design Code 31.3 has not mentioned any limitation for same size range.
2) As per Pressure Equipment directive ( PED ) regulation for Ductile material ,its elongation after rupture is no less than 14 %. But as per ASTM A193 B8 Cl.2 , mechanical properties Table 2 , elongation in 4 D. min % , is ( for bolts below 3/4"inch diameter ) is 12 . Are these 2 parameter comparable ?
Does it mean that, as per PED , B8 CL.2 material for small diameter is not sufficiently ductile ?
waiting for your replies.
Kind regards
Rahul