Wednesday, January 13, 2010

Re: [MW:4033] Impact

Dear Mr. Amarjit singh,

E 7018 C3 L electrode is OK. You will get impact propery with this electrode with out PWHT also.  I have done a procedure with this elcetrode and without impact test at -54 deg. C.

Thanks & Best Regards.

John.


On Tue, Jan 12, 2010 at 8:48 PM, amarjit Singh <amritas2001@gmail.com> wrote:
Dear all,
 
I am facing the problem of impact test at -60 deg C in welding.
 
The material is SA 537 Cl 1 and welding consumable used is E7018 C1L ( Advani make). as C1L contain Ni its weld should pass impact but the same is not.  where as impact is OK with E-7018 C3L electrodes.
 
can any body suggest ????

--
Amarjit Singh

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...