Dear Mr. Amarjit singh,
E 7018 C3 L electrode is OK. You will get impact propery with this electrode with out PWHT also. I have done a procedure with this elcetrode and without impact test at -54 deg. C.
Thanks & Best Regards.
John.
On Tue, Jan 12, 2010 at 8:48 PM, amarjit Singh <amritas2001@gmail.com> wrote:
Dear all,I am facing the problem of impact test at -60 deg C in welding.The material is SA 537 Cl 1 and welding consumable used is E7018 C1L ( Advani make). as C1L contain Ni its weld should pass impact but the same is not. where as impact is OK with E-7018 C3L electrodes.can any body suggest ????
--
Amarjit Singh
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.