Wednesday, January 20, 2010

Re: [MW:4112] RE: 4089] RE: 4088] Weld Efficiency

The attached files may of some help.

arun

On Wed, Jan 20, 2010 at 9:40 AM, Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> wrote:
in my opinion type 3 will used only when there is no RT, else all these welds shall be considered as type 1 only, in particular if you read the description for type 1 under table UW12
butt joints attained by double welding or by other means which will obtain the same quality on both sides.
When welded from one side only in type 1 , it must be demonstrated that the quality of the deposited weld metal on both sides of the joint meet the requirements of UW-35.
 
else you may refer flow chart in fig L-1.4.4. and select your joint efficiency


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Phirke, Praphulla D (GE Infra, Oil & Gas)
Sent: Wednesday, January 20, 2010 9:43 AM
To: pgoswami@sympatico.ca; materials-welding@googlegroups.com
Subject: RE: [MW:4100] RE: 4089] RE: 4088] Weld Efficiency
Importance: High

Hi Pradeep
Thanks a lot for your detailed explanation & I got the point also.
But in my current project, I had designed the pipes with Joint efficiency of 0.6 as Type B weld. After wards, due to material change, the provided thickness is coming slightly lesser than the required one & we want to maintain same schedule of pipes.
That's why We are thinking to have radiography.
 
What's your opinion on this?
 
Thanks
Praphulla


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of pgoswami@sympatico.ca
Sent: Wednesday, January 20, 2010 8:46 AM
To: materials-welding@googlegroups.com
Subject: FW: [MW:4098] RE: 4089] RE: 4088] Weld Efficiency


  

Dear Praphulla,

 

I have attached a schematic for illustration of various joints, for all the forum members. As per Table-UW-12, the joint in question is Type-3, which is single sided butt welds, without backing strips. This kind joint is permitted for type- A (L-Seam), B (Circ-Seam) , Type-C(Mainly Flange Joints).The limitations are specified in Table –UW-12

 

As per UW-12, the minimum efficiency for this type of weld permitted and required for code design is 0.60. One may perform RT over the code requirements but that is optional. From the description it's is Type –B weld on pipe , with the RT criteria specified in UW-11(a) (2).

 

Hence all stand points you may consider this joint as efficiency =.0.60.

 

Thanks

 

Pradip Goswami,P.Eng

Senior Engineer/Specialist(Welding-Metallurgy)

Engineering & Training Services Division

ONTARIO POWER GENERATION Inc.

PO Box-2000, RR-55(South)

Nanticoke, Ontario,N0A1L0

Tel:-(519) 587-2201, Ext 3107--in Nanticoke

          (416) 231-4111  (416) 231-4111 , Ext 5925--in Kipling,Toronto

Fax: (519) 587-6814

Email-pradip.goswami@opg.com.

  


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Bathula Raghuram (Mumbai - PIPING)
Sent:
Tuesday, January 19, 2010 6:40 AM
To: materials-welding@googlegroups.com
Subject: [Norton AntiSpam] [MW:4091] RE: 4089] RE: 4088] Weld Efficiency

I suppose this will be welded by GTAW process to obtain full penetration weld (which will give same quality of weld metal both sides) hence can be considered under type 1.

 

Even I would like to know which type of joint falls under type 3 (in my opinion only those circumferential welds which don't require full penetration), anybody give example?

 


From: Phirke, Praphulla D (GE Infra, Oil & Gas) [mailto:praphulla.phirke@ge.com]
Sent:
Tuesday, January 19, 2010 4:56 PM
To: Bathula Raghuram (Mumbai - PIPING); materials-welding@googlegroups.com
Subject: RE: 4089] RE: 4088] Weld Efficiency

Hi Bathula

Its simple Pipe to pipe joint single butt weld joint ( 4 to 8" Sch 10 pipes) .But considering the thickness & diameter its lying in Type 3.

Can we consider Type 1, but its for double weld butt joints?

 

Thanks

Praphulla

 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Bathula Raghuram (Mumbai - PIPING)
Sent:
Tuesday, January 19, 2010 4:50 PM
To: materials-welding@googlegroups.com
Subject: [MW:4089] RE: 4088] Weld Efficiency

What type of joint it is, if it is to be radiographed, why not consider under type 1 of table UW12

 


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Phirke, Praphulla D (GE Infra, Oil & Gas)
Sent:
Tuesday, January 19, 2010 4:30 PM
To: materials-welding@googlegroups.com
Subject: [MW:4088] Weld Efficiency
Importance: High

Hi All

As per ASME SEC VIII Div I, in Table UW-12 , for type No 3 weld joints, 0.7 joint efficiency is specified without any radiographic examination.

But If I performed radiography examination, then what joint efficiencies values I should consider for Full & Spot radiography? As per code & Table UW-12, its NA. 

 

Please guide me.

 

Thanks 

Praphulla D. Phirke 

Lead Engineer

GE Infrastructure

Oil & Gas

ASE-RC PV & HEX

John F. Welch Technology Centre

 

T    + 91-080-4088 5903  + 91-080-4088 5903

F   + 91-080-2841 2111

M   + 91-9886052515  + 91-9886052515

praphulla.phirke@ge.com

 

Odyssey, Phase - 5, Wing A, 2nd Floor,

Plot No 122, EPIP Phase II,

Whitefield Road, Bangalore 560 066

GE India Technology Center Pvt. Ltd.

 

GE imagination at work

 





THIS MESSAGE IS ONLY INTENDED FOR THE USE OF THE INTENDED RECIPIENT(S) AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED, PROPRIETARY AND/OR CONFIDENTIAL. If you are not the intended recipient, you are hereby notified that any review, retransmission, dissemination, distribution, copying, conversion to hard copy or other use of this communication is strictly prohibited. If you are not the intended recipient and have received this message in error, please notify me by return e-mail and delete this message from your system. Ontario Power Generation Inc.



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.




--
ARUNACHALAM.A
050-5257122

"If you open your heart, love opens your mind."

No comments:

[MW:35346] Cast-iron welding