Hi Bathula
Its simple Pipe to pipe joint single butt weld joint ( 4 to 8" Sch 10 pipes) .But considering the thickness & diameter its lying in Type 3.
Can we consider Type 1, but its for double weld butt joints?
Thanks
Praphulla
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Bathula Raghuram (Mumbai - PIPING)
Sent: Tuesday, January 19, 2010 4:50 PM
To: materials-welding@googlegroups.com
Subject: [MW:4089] RE: 4088] Weld Efficiency
what type of joint it is, if it is to be radiographed, why not consider under type 1 of table UW12
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Phirke, Praphulla D (GE Infra, Oil & Gas)
Sent: Tuesday, January 19, 2010 4:30 PM
To: materials-welding@googlegroups.com
Subject: [MW:4088] Weld Efficiency
Importance: High
Hi All
As per ASME SEC VIII Div I, in Table UW-12 , for type No 3 weld joints, 0.7 joint efficiency is specified without any radiographic examination.
But If I performed radiography examination, then what joint efficiencies values I should consider for Full & Spot radiography ? As per code & Table UW-12, its NA.
Please guide me.
Thanks
Praphulla D. Phirke |
Lead Engineer |
GE Infrastructure |
Oil & Gas |
ASE-RC PV & HEX |
John F. Welch Technology Centre |
|
T + 91-080-4088 5903 |
F + 91-080-2841 2111 |
M + 91-9886052515 |
|
|
Odyssey, Phase - 5, Wing A, 2nd Floor, |
Plot No 122, EPIP Phase II, |
Whitefield Road, Bangalore 560 066 |
GE India Technology Center Pvt. Ltd. |
|
GE imagination at work |