Hi All
As per ASME SEC VIII Div I, in Table UW-12 , for type No 3 weld joints, 0.7 joint efficiency is specified without any radiographic examination.
But If I performed radiography examination, then what joint efficiencies values I should consider for Full & Spot radiography ? As per code & Table UW-12, its NA.
Please guide me.
Thanks
| Praphulla D. Phirke |
| Lead Engineer |
| GE Infrastructure |
| Oil & Gas |
| ASE-RC PV & HEX |
| John F. Welch Technology Centre |
| |
| T + 91-080-4088 5903 |
| F + 91-080-2841 2111 |
| M + 91-9886052515 |
| |
| |
| Odyssey, Phase - 5, Wing A, 2nd Floor, |
| Plot No 122, EPIP Phase II, |
| Whitefield Road, Bangalore 560 066 |
| GE India Technology Center Pvt. Ltd. |
| |
| GE imagination at work |