Tuesday, November 16, 2010

[MW:8290] Re: PQR mentioning position 3G and our WPS stated 1G

Dear,
You just delete position 1 g from wps and write All,
As per ASME Section IX if WPS is qualified in any one position of 1G
to 6G it is qualify for all the position.
Then u can attached nos of PQR with dirrent position following the
same WPS.

Regards
Israr Ahmed
Tata Projects Ltd.India
+919930308261

On Nov 11, 2:35 pm, Zulfan <zul...@insing.com> wrote:
> Dear all,
>
> please advice in our PQR mentioning position 3G and our WPS stated 1G
> is the WPS able to apply or need to run again PQR again?
> code ASME sec IX
>
> Thank
> zul

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34916] Applicability of Impact requirement as per ASME B31.3

Dear All, Design code – ASME B31.3, Welding Code- ASME BPVC SEC IX Material  to be used used during Fabrication - SA 333Gr6 (P No.1 G...