Tuesday, September 10, 2024

[MW:35223] 10% & 12.5 % ACCEPTANCE CRITERIA BASE ON CODE AND STANDARDS

Dear Inspector Experts,

In some PMI reports, I found a comment written on the bottom side. The measured value of material alloying elements shall be within 10 percent of the specified level, and 12.5 percent for the weld base metal. From where tolerance has been taken. is it mentioned in any codes and standards & what standard did we refer to?


Thank you for your support & Information.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/dd67d2f1-2e91-4abe-9a5b-5647f30a0535n%40googlegroups.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...