Tuesday, September 10, 2024

[MW:35205] Re: Clarification on Subsize Impact Specimens for PQR According to API 650

dear pl provide all three value for specifimen, if one specimen below average but within 2/3 range it is accepted.

On Thursday, August 29, 2024 at 10:09:07 AM UTC+3 Binto George wrote:
 Dear Experts?

We obtained a value of 26J(avg) for P1 G2 material during procedure qualification with impact requirements, whereas the acceptance criteria according to API 9.2.2.5 is 27J(Avg). We used a subsize specimen of 7.5 x 10 mm. Is there any relaxation or allowance for subsize specimens in this context? If so, where can I find this information?  

Regards,
Binto George

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/26d54822-dcf8-4db5-a252-a618d6864cd0n%40googlegroups.com.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone