Tuesday, September 10, 2024

Re: [MW:35229] Re: UCS 67(a)

In drawing Impact test requirements will give, if it's yes, you have to use impact tested WPS. If it's NO you can use without impact tested WPS.



On Fri, 6 Sept 2024, 11:45 am Mohd Siraj, <mohd52100@gmail.com> wrote:
Hello Experts,

Scenario
We have a weld joint where 10 mm thick SS pipe (P 8) is welded to 40 mm thick CS (P 1) flat cover. It is a partial penetration weld with 10 mm groove depth. The construction code is ASME Sec VIII Div. 1 and MDMT is -40 degree celcius. I am willing to use ER 309 LMo. 

Query
1. Do i have to use WPS with impact at or colder than -40 degree celcius, or only impact tested filler is enough? or, 
-YES

2. PQR without impact test will do if i am using non impact tested filler?
-NO.

Regards,
Pravin Katkar

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/d06e2414-1c71-4660-81a6-2e4a4237823fn%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAEabyKmGeQUCUe%3D9JvR_HThEzLZZN9zCyqyVrRsWS7778b-ErQ%40mail.gmail.com.

No comments:

[MW:35197] WELD DISTANCE AS PER API 650

Daer expert what is the allowable distance between Vertical to Vertical & Horizantol to Horizantol Joints. -- https://materials...