Re: [MW:32241] PWHT REQUIERMENT FOR PIPING AND PIPELINE

Yes brother compulsory you have to do preheating but you need to maintain the temperature so my recommendation is better for coil induction coil heating is good to maintain the temperature 

On Wed, 14 Apr, 2021, 7:55 am QA/QC, <adnanziad49@gmail.com> wrote:
Dear masters 

we want to weld a pipeline api 5l x70 thhikness 28 mm so we want to know the requierement of PWHT CODE API 1104 

AND ALSO FOR A333 GR 6 THICKNESS 45 MM CODE B31.3  . PWHT REQUIERMENT 

CAN ANYONE CLARIFY IT FOR ME 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/1123834c-5b79-4fd8-8864-0deaf7c0e3fcn%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CANO0gOA-fhviVkNiDBO%2BJbYZL6VFePdDzS_N-fAiRfhovazyzA%40mail.gmail.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...