Re: [MW:32247] CLAD MATERIALS -WELDING WPS /PQR ERNiCrMo3 / 7018-1 Combination

I know that in clad welding You MUST do at least 3 overlays, otherwise the clad won´t word as it should be. You can use 2 WPS, for this pipe welding. One for ER NiCrMo3 and other to 7018-1. 
According to some codes you will need many corrosion tests to approve the PQR, and for the root and hot pass you´ll need more than 3 overlays too. You will need to do all NDT for the ER NiCrMo3 before start the SC welding...
Alcindo O. J. Jr.
21 96676-1511



Em qua., 14 de abr. de 2021 Ă s 11:37, pravean ashok <gujulapravean@gmail.com> escreveu:
Dear we have in our previous project
Clad material in AlHosan gas Abudhabi and we found there is no issue in that material go a head 


Regards
Pravean

On Wed, 14 Apr, 2021, 11:42 am PK M, <pkmqaqc@gmail.com> wrote:

Hi experts,

 

CLAD MATERIALS -WELDING

 

We have the following Clad Pipe and we are preparing WPS /PQR to weld this SPOOL.

As I know we need to use ERNiCrMo3 / 7018-1 Combination (if GTAW+SMAW) to Complete weld.

But if anyone is having experience with this, please advise whether we will go with

 

GTAW - ER NiCrMo3 ( Root & Hot )

 

SMAW – E7018-1 (Balance Filling /Capping).

 

Please Explain any troubles may have happened regarding dilution or not.

 

Need Aramco and International code reference? If any one has a sample WPS/PQR Please share with us.

 

Any corrosion test or NDT

 

Waiting for your scientific and specific reply.

 

Thanks in Advance.

 

Pkm

pkmqaqc@gmail.com

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAFoQ_neYBsYs0Ly8VaMw5SMMw_ueaaAZM4QQs7B_KryHZkjhRQ%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CANO0gODQN_xqMn6tj-oMEv8zh98k9%3DmtUZa-yMDUuFrSxqEncg%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CANT8xKQOUHAyCEjT53zWy5BVzg%3DLG%3Dp6_RQXNTMMzBwK5GHfug%40mail.gmail.com.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...