Update: QW-191.2.1, Subparagraph (a) revised – The ultrasonic examination in QW-142 for welders and in QW-143 for welding operators may be conducted on 1/4 in. (6 mm) thick or greater.
On Friday, August 24, 2012 at 2:12:07 AM UTC+4, Ajay Ror wrote:
-- Background – Minimum thickness for applicability of UT examination reduced to be consistent with Construction Codes, ASME Section VIII Divisions 1 and 2.
On Friday, August 24, 2012 at 2:12:07 AM UTC+4, Ajay Ror wrote:
Dear experts
is there any new ammandmends for welder qualification,where we can
accept UT Test istead of Destructive/RT Test ?
Regards
Ajay Kumar