Skip to main content

NACE Standard MR0175 accepts ductile iron to ASTM A 395. Can we use ASTM A 536 Grade 60/40/18?


Question: I have a query regarding material suitability on a recent enquiry to supply a nodular iron screw compressor. NACE Standard MR0175 accepts ferritic ductile iron to ASTM A 395. My question is if our existing in-house standard of ASTM A 536 Grade 60/40/18 will comply as a direct alternative. On the face of it tensile strength, elongation are similar at 415N/mm2 and 18%!
Answer:
The ISO Maintenance Panel cannot advise on materials selection issues. The role of the Maintenance Panel is solely to ensure that NACE MR0175/ISO 15156 (the current edition of NACE MR0175) is clear in its stated requirements and is kept up-to-date.
Should you wish, the procedure to propose an amendment to the standard to include ASTM A 536 Grade 60/40/18 is described in
“01. Introduction to ISO 15156 Maintenance Activities” on the Web site
www.iso.org/iso15156maintenance.
This question is in relation to NACE MR0175/ISO 15156-2 Annex A.2.4.3
Reference: ISO 15156 Maintenance Panel Inquiry #2005-27

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...