Wednesday, June 6, 2018

[MW:27938] minimum leak path calculation for tube to tubesheet joint

dear experts,
i require the calculation of the minimum leak path calculation for tube to tubesheet joint.
below are the deatils:

Full strength weld Joint

Design temperature: 150 °C

Tube sheet Material: SA 266 gr.2

Seamless Tube Material: SA 266 gr.2

Tube OD: 19.05 mm

Tube Thickness: 1.91 mm

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...