Question:
MR0175 part 2, Table 1: Does the intent to only load in compression, regardless of resultant stresses, fulfill the requirement for exclusion?
Answer:
The exclusion applies to components loaded in compression. It does not apply to equipment, assemblies, or aggregate parts loaded in compression. However, due to part geometry, constraint, bending, friction, or other factors, local stresses within a single component may have a significant tensile element. In such cases the likelihood of environmental cracking, and its consequences, shall be considered before invoking this exemption.
This question is in relation to NACE MR0175/ISO 15156-2
Reference: ISO 15156 Maintenance Panel Inquiry #2015-04


No comments:

[MW:35536] RANGE ASME SEC IX

Dear All we have qualified WPS for ( ASME SEC IX) 1. BASE plate 8 mm ( 8TO 16 mm RANGE WITH IMPACT )  2 . BASE plate 25 mm ( 16TO 50mm RANGE...