Hi Prasad,
-- stress revealing cracks will be there .but dont worry ,Its the property of the material ( low ductility). please use Ni based base layer ,on top deposit ST-6.
Kr
shyamal
On 17 April 2018 at 10:05, N VENKATESWARA PRASAD <weldengr.velosi@gmail.com> wrote:
Dear Experts,--Please share your experience stellite 6 hard facing by GMAW ( CMT/ STT ) process to achieve crack free deposit.RegardsPrasad
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com .