Skip to main content

Re: [MW:19930] storage tank hydrotest with sea water.

Please refer OISD 129 for HT procedure of above ground tanks. They also provided guideline on water quality. It permits usage of sea water also but with testing on corrosives like pH. You may use dosing chemicals in sea water.
 
API 650 prohibits storage of water for more than 14 days in contact with metal except biocides are added.
 
API 650 - 7.3.6.3 Specifying the test water quality. Potable water is preferred for hydro-testing. This does not preclude the use of
condensate, reverse osmosis water, well water, river water, or sea water. The Purchaser shall consider issues
such as low temperature brittle fracture, freeze damage, amount of suspended solids, sanitation issues, animal/
plant incubation and/or growth, acidity, general corrosion, pitting, protecting against cathodic cells,
microbiologically-induced corrosion, material dependent sensitivity to trace chemical attack, disposal, rinsing,
3) For the following metallurgies, describe on the Data Sheet, Line 14, (using a Supplemental Specification) any
additional restrictions on the water quality.
a) Carbon Steel—For carbon steel equipment where water contact exceeds 14 days, including filling and
draining (e.g. consider adding an oxygen scavenger and a biocide, and raise the pH by the addition of
caustic).
b) Stainless Steel—See Annex S.
c) Aluminum Components—See Annex H.

On Sun, Oct 13, 2013 at 12:57 AM, Manoj John <manojacgnr@gmail.com> wrote:
Dear members,

Please share information and procedure for hydrostatic testing of API storage tank with sea water.

Thanks in advance,
Manoj.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.



--
PAVAN SHARMA
702, CLASSIC'S RESIDENCY
PLOT-32, SEC-42A
NERUL (W) NAVI MUMBAI - 400706

OFF: HPCL, MUMBAI REFINERY
         022 25076126

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...