Re: [MW:19930] storage tank hydrotest with sea water.

Please refer OISD 129 for HT procedure of above ground tanks. They also provided guideline on water quality. It permits usage of sea water also but with testing on corrosives like pH. You may use dosing chemicals in sea water.
 
API 650 prohibits storage of water for more than 14 days in contact with metal except biocides are added.
 
API 650 - 7.3.6.3 Specifying the test water quality. Potable water is preferred for hydro-testing. This does not preclude the use of
condensate, reverse osmosis water, well water, river water, or sea water. The Purchaser shall consider issues
such as low temperature brittle fracture, freeze damage, amount of suspended solids, sanitation issues, animal/
plant incubation and/or growth, acidity, general corrosion, pitting, protecting against cathodic cells,
microbiologically-induced corrosion, material dependent sensitivity to trace chemical attack, disposal, rinsing,
3) For the following metallurgies, describe on the Data Sheet, Line 14, (using a Supplemental Specification) any
additional restrictions on the water quality.
a) Carbon Steel—For carbon steel equipment where water contact exceeds 14 days, including filling and
draining (e.g. consider adding an oxygen scavenger and a biocide, and raise the pH by the addition of
caustic).
b) Stainless Steel—See Annex S.
c) Aluminum Components—See Annex H.

On Sun, Oct 13, 2013 at 12:57 AM, Manoj John <manojacgnr@gmail.com> wrote:
Dear members,

Please share information and procedure for hydrostatic testing of API storage tank with sea water.

Thanks in advance,
Manoj.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.



--
PAVAN SHARMA
702, CLASSIC'S RESIDENCY
PLOT-32, SEC-42A
NERUL (W) NAVI MUMBAI - 400706

OFF: HPCL, MUMBAI REFINERY
         022 25076126

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.

Comments

Popular posts from this blog

Re: [MW:34105] SA266 GR4N 4 Cycle SPWHT

Hi,  You are correct, Minimum refers to the one cycle for which this part will expose until final work shop PWHT. hence mill test certificate shall include this.  Max. SPWHT, refers to additional cycles of heat treatment that are reserved for future repairs during equipment lifetime.  Again, these simulated no. Of cycles shall be specified in MTC.  The idea is we need to make sure that steel mechanical properties are not compromised upon exposure to multiple repairs (i e 4 cycles in your case).  One could say, if steel is subjected to 4 cycles and is ok, then it should by defacto be good for one cycle, yet, this is wrong assumption cause mechanical problems and microstructure of materials varies accordingly based on no. Of cycles for which material will expose. This is apparent in alloy steel and especially for impact test values as an example.  In your case, this forged CS with properties before PWHT can be understood to be " as forged" condition (i.e. Wit...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...