An experience UT operator with A-Scan could size this defect

    best regards

    Dr. Georgios Dilintas

    Authorized Nuclear Inspector
    Authorized Inspector Supervisor
    API 510 Inspector

    I&F REGIONAL TECHNICAL MANAGER
    BUREAU VERITAS HELLAS

    Tel: +30 210 40 63 113/4
    Fax: +30 210 40 63 118
    Cell: +30 69 44 64 62 04
    (See attached file: Dilintas_George.vcf)

Gurmeet singh Mehta ---14/01/2014 17:49:58---Dear It is not easy to check with destructive testing. If you want tha we should

From: Gurmeet singh Mehta <gurmeetpmehta@gmail.com>
To: materials-welding@googlegroups.com
Date: 14/01/2014 17:49
Subject: Re: [MW:19860] Side wall lack of fusion
Sent by: materials-welding@googlegroups.com




Dear
It is not easy to check with destructive testing. If you want tha we should identify the location of the defect. send the sample to lab. Ask the lab to get a cross section and carry out macro examination which will help you to measure the defect.

Regards

Gurmeet

On Thu, Jan 9, 2014 at 10:50 PM, Sara Vana <krmech2000@gmail.com> wrote:

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit
https://groups.google.com/groups/opt_out.

This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...