Monday, September 23, 2013

Re: [MW:18727] QW403.7 is where in ASME IX 2010

Table QW-451.1 has been revised to incorporate the provisions previously found in QW-403.7. That paragraph dealt with how to qualify for welding of materials that were over 8 inches (200 mm) in thickness, and it has been deleted. There is a new line in QW-451.1 that says that, for test pieces that are 6 inches (150 mm) thick, the minimum thickness qualified is 3/16 inches and the maximum thickness qualified is 1.33 times the test coupon base metal and weld deposit thickness.


On 22 September 2013 21:53, mohd <mohd52100@gmail.com> wrote:
deae expert,
 can anybody tell me where is QW403.7 in ASMEIX 2010,
or is it deleted? i checked in 2007version also not available.

regards
mohd.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone