From:
Sent: Monday, September 23, 2013 11:09 AM
To: Nagarajan, Swaminathan
Subject: Weld inside grinding
Dear Sir,
Normally tie in joints will be considered as Golden Joints and hydro test of that joint will be waived. the client has instructed contractor that the if the tie in is done by welding a flange with the existing pipe, it shall be hydro tested using a special device called Flange tester. To use the flange tester a part of the flange tester will go inside the pipe beyond the welding. In this case the root reinforcement will prevent the part from going inside. For this the root reinforcement shall be flush grinded. But it's a not a normal practice to grind the root. I am unable to find any reference in any codes or standard referring to this. Please advise appropriately.
Thanks & Regards,
Sankara narayanan.R
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
No comments:
Post a Comment