--Dear Experts,
We have performed a PQR for 25 thk plate , P1(SA 516 GR-70 ) To P8(SA 240 TP-316L). These PQR has been stress relieved at 620° C & impact tested at -20°C.
The testing laboratory has noted down only the joule values for the impact test, but they have not noted the Lateral Expansion Values P-8 Material.
The Avg. Joules Values observed are as follows:
Weld-72.67 J
HAZ(GR-70)-35.33J
HAZ(GR-316L)-158 J
PARENT(GR-70)-51.33J
PARENT(GR-316L)-298 J
Now our TPI says that for GR-316L Lateral Expansion Values is must for acceptance of the PQR.
Is it so?
Or based on these joules values these PQR can be accepted & used for weld having requirement of impact test at -20°c
Thanks & Regards
Ankit Patel
Engineer Quality
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment