Skip to main content

[MW:14315] Re: 14305] ENiCrMo6 - AC operating

please allow me to answer your questions.
1, YES. Just do it.
2, T=Tungsten, (W) . This element should be W, Maybe our company print it wrong, I will inform them to correct it.
 
Roy
 
 
 
Sent: Friday, May 18, 2012 8:55 PM
Subject: Re: [MW:14305] ENiCrMo6 - AC operating
 
Thanks Mr.Saroj,
 
Please clarify the following points.
 
1) Are these mechanical values indicated in the catalogue can be chieved after welding with AC current of 150 to 170 Amps for 4mm electrode?
 
2) What is the "T" alloying element mentioned?
 
Regards,
 
Srinivasan

On Fri, May 18, 2012 at 11:05 AM, saroj kumar <sarojselva@gmail.com> wrote:
Dear Srinivasan,
 
Yes, the SMAW electrode ENiCrMo-6 is available for welding 9% Nickel steel base material for
Low temp application with AC.
 
You can go for BOHLER brand FOX NIBAS 60/15, which is highly suitable. The catalogue is attached
herewith for your perusal.


Thanks/Best Regards,
 
M.Saroj Kumar
Chennai,India.
 
On Wed, May 16, 2012 at 4:58 PM, Srinivasan Jagannathan <jsrisud@gmail.com> wrote:
Dear Experts,
 
We have a job to be welded with ENiCrMo6 which operates on DC.
 
We need to weld with AC current due to Arc Blow / Magnetism.
 
Is it possible to have SMAW electrode of same specification, operating on AC without compromising Mechanical Properties?
 
Please advice.
 
Regards,
 
Srinivasan
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to mailto:materials-welding%2Bunsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to mailto:materials-welding%2Bunsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


 
--
J.SRINIVASAN

GENERAL MANAGER - TRAINING

D&H SECHERON - INDORE

Mob: 7898989756

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...