Hi,
 
If Ur code of test is ASME-IX, then for an Example, refer QW-255 for FCAW Process , heat input is a Supplementary variable if U have Impact test, hence limit Ur parameters as per the variable table.
 
Then Current ,  Volt, travel speed are non Essential variable , if there is no Impact Test for Ur PQR.
 
In PQR U should right, what U observed the actual parameters and should weld as per the welding paramaters recommended for a partiuclar brand from the consumable manufacturer. And in WPS, it is purely based on Impact or Non Impact test conditions, U should refer Essential variable table .
 
If there is no impact test and also heat input is not an essential varaible, then U can refer to the consumable manufacturer's recommendation for welding parameters, for each size of electrodes or Fillers.
 
I think this is enough.......
 
Cheers,
Sarav
 
 
 
 
 

 
 
 
On Wed, May 30, 2012 at 9:17 PM, senins welo <senins054@gmail.com> wrote:


Dear experts,
         what is the range of welding parameter (CURRENT,VOLTAGE,TRAVEL SPEED,ETC.) for WPS  from PQR.? OR how based parameter in WPS.I want ur clarification.

thanks,

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...