Wednesday, December 28, 2011

Re: [MW:13351] Hydro test for different pressure

No. Over pressurising may lead to failure. In case of absolute necessity check with designer. Gopal
Sent from BlackBerry® on Airtel

From: Kanagarajan G <g.kanagarajan@gmail.com>
Sender: materials-welding@googlegroups.com
Date: Wed, 28 Dec 2011 11:08:39 +0400
To: <materials-welding@googlegroups.com>
ReplyTo: materials-welding@googlegroups.com
Subject: [MW:13346] Hydro test for different pressure

Hi,
 
Shall we carryout two different hydro pressure packs together in one hydro test for the maximum one.
 
For example, One test pack 30 PSI and another test pack 200 PSI.(Material same)
 
Regards,
 
Kanagarajan.G


 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone