Dear Sir,
According to ASTM A370 part 26.3, the choose of temperature reduction or changing the acceptance criteria or both of them is based on your contract. If you need to change the acceptance, you can use table 9 and if you have to change temperature you can use table UG-84.2 of section 8, div.1.
But here we have a note, but it is my interpretation.
The reduction in the temperature (if needed) shall calculate from the diference between the actual thickness of the material and the size of the specimen. In your case because you use two different processes, we can consider each process as an individual thickness. So you may make a set of impact specimens from GTAW with 3.33x10 mm sub-size standard specimen and a set of specimens from SMAW with 5x10 mm sub-size standard specimen which both of them do not need any reduction in temperature because in the case of GTAW the nominal thickness is 4mm and your specimen is 3.33 and 3.33 is mor than 80% of 4 mm. Also it is true about SMAW part.
In the othe way, you can consider that you wand make specimens from multi-process welded joints regardless of the processes. In your case you can make a 7.5x10 sub-size standard specimen without any reduction in the temperature because 7.5mm is more than 9mmx80% or 7.2mm.
Regards
On Wed, Dec 21, 2011 at 11:30 AM, james gerald <gerry_tup@yahoo.com> wrote:
Sizing can be done either at the root or cap and subsize of 5mm can be obtained with the notch located in the particular process.Yes the test temperature of -40.1°C. is correct.If the Full size(10x10mm) requirement is 34J then for subsize(10x5mm) 16J is acceptableThanks & Reagrds
J.Gerald Jayakumar
00968-93281596From: Rajagopal Kannan <rajagopal.kannan@gmail.com>
To: materials-welding@googlegroups.com
Sent: Wednesday, December 21, 2011 9:57 AM
Subject: Re: [MW:13244] IMPACT TEST -SUB SIZE
--Hi,It is not practical to go for 5mm thk. with the weld deposit of 5mm.You have to go for lesser dimensions.Thanks,K.RajagopalOn Wed, Dec 21, 2011 at 8:15 AM, Sundaram Elumalai <Elumalai.Sundaram@starfab.com.sa> wrote:
--******************************************************************************************Hi,Now we are qualifying two new PQR for new project for less base metalthick. (9mm). Code AWS D1.1ROOT / HOT Pass -GTAW (deposited 4mm)Fill/Cap - SMAW (deposited 5mm)We need to perform the impact test as per Client Welding spec for each process.In this case, we have to go for Sub size with temperature reduction.Client Welding spec requirement is minimum - 29 °C.If I go with 10x5mm sub size, I need to reduce 11.1 °C and test to bedone at -40.1°C. ( -29 -11.1)Then Joule value will considered as per ASTM 370,16 J from the belowsecond table.Is it correct ?With Kind Regards,S.Elumalai.
CONFIDENTIALITY NOTICE
This e-mail and any attachment are confidential and may be privileged or otherwise protected from disclosure. It is solely intended for the person(s) named above. If you are not the intended recipient, any reading, use, disclosure, copying or distribution of all or parts of this e-mail or associated attachments is strictly prohibited. If you are not an intended recipient, please notify the sender immediately by replying to this message or by telephone and delete this e-mail and any attachments permanently from your system.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
M. Shokri Arfaei
International Welding Engineer (IWE)
ASNT NDT Level III
ERI Metallurgy Lab. Manager
Tel: +98-21-66282127
Fax: +98-21-66282779
Please don't print this e-mail unless you really need to. BeGreen!
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment