Tuesday, December 27, 2011

RE: [MW:13321] Identification of thickness on Radiography films.

Dear Mr.Jean Station,
Thanks, I know it is not in any code (i.e.Sec-V Artical-2) or any other code but as far as for interpretor it is very difficut to review numbers of Radiography films & identify the IQI selection whether it is correct or wrong. If ready reference of thickness on Radiography films it is easear to interpret films in time . As far as my experience till date there was no any issue of indicate thickness on RT Films but; may be it is not confirm in any code; vendor/techiicians may take dis-advantage for the same and might have a change to use wrong IQI which may not be possible to controll quaity of Radiography by surveyor/interpretor because every time it is not possible to serch each documents for find out actual/thickness range used for Radiography.

Please go through my below mail again and advise.

Regards
RK Vichare

----- Original Message -----
From: Jean Staton <Jean.Staton@metco-ndt.com>
To: materials-welding@googlegroups.com
Sent: Thu, 22 Dec 2011 21:58:34 +0530 (IST)
Subject: RE: [MW:13267] Identification of thickness on Radiography films.

I don't know of any Code that mandates putting thickness on the actual radiograph, although since there are many codes, there may be. The A.I.'s /third parties I've always dealt with know to look at the prints/ISO's, etc. There is usually a report that indicates the thickness. It is up the third party, A.I. to read the report to find information regarding the radiograph and from there to ascertain whether correct IQI has been used. If we have room on the I.D. we will put the thickness on the report but if not, all information is on the report.

jean

-----Original Message-----
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Ramchandra vichare
Sent: Thursday, December 22, 2011 5:00 AM
To: materials-welding@googlegroups.com
Subject: [MW:13257] Identification of thickness on Radiography films.

Dear Experts,

During Interpreting Radiography films at one of my vendor's works, I observed that, there is no identification /indicate thickness of job on film so I rejected the film. As far as generally everyone related field experience persons are know unless identification of thickness on film it is very difficult to know which penetrameter to be used but my vendor is arguing for the same. According to him one of "Level III" person insisit them there is no need to mentioned thickness in Radiography films and it sufficient if it indicate in Radiography interpretion report.
Suppose in piping number of joints/piping spools are comming with verious thickness in same report in such case it is possible to identify required penetrameter ? My anser is no, each Radiography films must be indicat thickness of joint/job. Requested to suggest/advise.

Sincerely yours,
RK Vichare

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

DISCLAIMER: The information contained in this e-mail may be confidential and is intended solely for the use of the named addressee. Access, copying or re-use of the e-mail or any information contained therein by any other person is not authorized. If you are not the intended recipient please notify us immediately by returning the e-mail to the originator.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...