Skip to main content

RE: [MW:12582] 3.5% Nickel steel

Hi Mrithyunjay,
 
If sour service requirements i.e MR-0103, is applicable then the maximum allowable hardness is  22HRC (237HBW or 248HV 10)
 
Several grades of 3.5% Nickel steel is accepted in ASME Code. If you look carefully in Sec-II ,Pt-A, Grade D has maximum "C" restriction of 0.17%, while for grade E & F this limit is 0.20%. The compositional limits for all other alloying elements are  identical for all 3.5% Ni grades.
 
The default SMAW welding electrode (assuming this was the weld process used)  for this grade of 3.5% Nickel steel is E-8016/8018-C2 (Max C -0.12%).When hardness restriction is imposed then welding electrodes could be classified as E-7016/7018-C2L (max C-0.05%).
 
SFA 5.5 ,Annex-A elaborates the philosophy. If  the scenario is such that:-
  • PWHT is not required as per design code or project specifications
  •  low temperature notch toughness is to be met 
  •  hardness requirement is imposed 
 then low carbon grade E-7016/7018-C2L would be advisable to use in addition to the usual cautions on heat input.
 
Here the issue of higher hardness is on the HAZ of the  capping pass.Essentially  if this scatter is isolated, re-evaluate the reading. Otherwise use a lower diameter electrode, typically 1/8" for the final pass and increase the number of runs.This would effectively do better tempering of the capping weld and adjacent HAZ and would help to control the hardness.
 
While welding 3.5% Nickel steel do not try to exceed the preheat and interpass temperature.Since both the factors tends to reduce the acicularity of 3.5% Nickel weld and HAZ , it could have negative impact on notch toughness values.
 
Thanks.
.
Pradip Goswami,P.Eng.IWE
Welding & Metallurgical Specialist & Consultant
Ontario,Canada.
Email-pgoswami@sympatico.ca,
 
 
 
 


 
 
 From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Rajagopal Kannan
Sent: Thursday, September 29, 2011 1:24 AM
To: materials-welding@googlegroups.com
Subject: Re: [MW:12578] 3.5% Nickel steel

Dear Mrithyunjay,
For the 3.5% Nickel steel, it is client to say what hardness they want.
Nace requirement is 248 HV10.
The post heating of 350 Deg.C does not seem to have much impact on HIC testing.
Thanks and Best regards,
K.Rajagopal

On Thu, Sep 29, 2011 at 9:09 AM, mrithyun jay <mrithyun.j@gmail.com> wrote:
Hello Everyone,

Currently I am qualifying a welding procedure for a pressure equipment   which involves 3.5% Nickel steel. The design code is ASME VIII Div 1,
the query is what is max. permitted HAZ hardness for this material. I   have got two indentations 278 and 280 vickers 10kg in cap HAZ, whilst
the others are well below 250HV10.

WT of the coupon was 10.97mm and I have done a post heating at 350°C   for 2 hours (assuming it would be beneficial to address HIC). I   haven't done any PWHT.

NB: Client is not sure of the permitted max. hardness, from memory -   being a ferritic steel, I would assume max. permitted is 250 for NACE
applications.

I would like a confirmation from the group members, whether my   assumption is correct?

Thanks everyone

Mrithyunjay.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...