Can you please share here in which statement of API 582 that mentions about it?
Thanks and regards,
Endri
-- On Sun, Aug 14, 2011 at 2:55 PM, Raghuram Bathula <raghurambathula@gmail.com> wrote:
i guess the %Cr <2.25 in this material, in that case back purging is
not required as long you have a qualified PQR without purging.
Generally purging is recommended for materials with Cr >2.25% (refer
API 582).
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.