It doesn't need purging, of course doing it is better but it's not critical...!!!
Regards
Ramin Kondori
QC/Welding Engineer
IWE AT 0070
On Sun, Aug 14, 2011 at 11:25 AM, Raghuram Bathula <raghurambathula@gmail.com> wrote:
i guess the %Cr <2.25 in this material, in that case back purging is
not required as long you have a qualified PQR without purging.
Generally purging is recommended for materials with Cr >2.25% (refer
API 582).
On Sun, Aug 14, 2011 at 11:24 AM, sri lakshmi <2002mgs@gmail.com> wrote:
> back purge is must as it prevents oxidation which will result in loss of
> joint strength.
> regards
>
> On Sat, Aug 13, 2011 at 9:24 PM, Endri Prasetyo <endri.prasetyo@gmail.com>
> wrote:
>>
>> Dear Experts,
>> When we join the material of 12Cr1MoVG by TIG welding (root pass), is it
>> possible/acceptable if we don't apply gas purging for back side?
>> Please advise.
>> Regards,
>> Endri
>>
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment