Saturday, August 20, 2011

[MW:12284] Hydro test pressure for Pipes SA 312 TP 304

Dear All,

Please anybody can clarify me regarding Hydro test pressure for Pipes
SA 312 TP 304

I have already read the SA 999 clause no. 22.2 Hydrostatic test,
after
reading also i have not cleared that what is the code requirement.


Regards,

Kapil Bhamburdekar

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...