Re: [MW:9142] Thickness qualification range for duplex SS with PWHT (ASME IX)

Do you have impact test requirements?
Any how at this temperature you are in the full austenitic range the 1,1 (like in the case of AC3) restriction applies

best regards

Dr. Georgios Dilintas

Authorized Nuclear Inspector
Authorized Inspector Supervisor

I&F Regional Technical Manager
Bureau Veritas Piraeus - Greece
Tel: +30 210 40 63 113/4
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04