Thursday, December 23, 2010

Re: [MW:8910] Which page shows in AWS D1.1- E 7018 qualifies E 6013-reg

Please refer to AWS D1.1 Edition 2008 clause 4 requalification,table 4.12 can answer your query.

one of the Essential variable which require for requalification is when the welder qualifies in one F number and he welds with greater F number than the previous one.

But in your case,the welder already qualified using 7018 electrode with higher F number(F4) and he can weld using 6013 electrode with lower F number(F2) requires no seperate qualification.


Thanks and Regards,


Thiru.

--- On Thu, 23/12/10, k7moorthi <k7moorthi75@gmail.com> wrote:

From: k7moorthi <k7moorthi75@gmail.com>
Subject: [MW:8909] Which page shows in AWS D1.1- E 7018 qualifies E 6013-reg
To: "Materials & Welding" <materials-welding@googlegroups.com>
Date: Thursday, 23 December, 2010, 3:32 PM

Dear all,

If  Welder Qualified in E 7018,is it required for E 6013, Construction
Code AWS D1.1
Specifically in Pre Qualification.
please refer page no. in AWS D1.1.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...