Wednesday, December 22, 2010

RE: [MW:8868] ELECTRODE - Change in AWS classification for weld overlay

Each AWS classification of A-No. 8 analysis of table QW-442, shall require separate WPS qualification (QW404.37).

-----Original Message-----
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of KUMAR
Sent: Wednesday, December 22, 2010 10:26 AM
To: materials-welding@googlegroups.com
Subject: [MW:8866] ELECTRODE

Dear sir,

In weldoverlay smaw process welding, the changing electrode E309L in
place of E316L is acceptableor not? It mentioned in WPS that E309L
is for barrier Layer and E316L for clad layer

Thanks and regards
M.Kumar


Filtered by Hosted Filtering


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...