It is permitted, but you have to make sure that you ground smooth the weld that you are going to weld on again
On Wed, Dec 1, 2010 at 2:18 PM, Santosh Gaikwad <santoshcwi@gmail.com> wrote:
Dear all,
my company is manufacturing ASME U Stamp vessel,as per the drawing one of the nozzle location is very closed to the dish head circumferential seam,even Dish head welding & nozzle welding are touching together .
is it acceptable as per ASME Sec VIII div I .
please do reply.
--
Thanks & Regards.
Santosh Gaikwad
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment