Tuesday, October 26, 2010

[MW:7811] weaving issue

Dear Friend,
 
Really,on weaving NCR  can be issued, because when weldjoint  is not impact value tested PQR is not notch toughness tested.,just mentioned in WPS three times electrode or 10 mm which ever is less. according to my knowledge code silent on this,weaving width increase the heat input at weldment due to this it ,effect low impact value.
friends kindly elaborate this issue with reference code and articles.
 
waiting for your valuable comments.
Thanks and regards
Sujay

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...