On Tue, Jun 22, 2010 at 5:45 PM, v dhinesh <dhineshsir@gmail.com> wrote:
-- Dear Mr.Prasad,
Thanks for your feed back. But which electrode we use for the root.
Regards,
DHINESHOn Tue, Jun 22, 2010 at 9:50 AM, N VENKATESWARA PRASAD <weldengr.velosi@gmail.com> wrote:
Dear Dhinesh,SA 333 Gr.3 ( 3.5 Ni alloy steel) is low temperature steel used upto - 100 C which comes under P 9 group and electrode used shall be E 8018 C2. E 6013 and E 6018 are not at all suibtable for welding of the above material.regards.
N.V. PRASADWELDING ENGINEERVELOSI CERTIFICATIONOn Mon, Jun 21, 2010 at 1:25 PM, dhinesh <dhineshsir@gmail.com> wrote:
Dear All,
I would like to understand what are the causes appear if you
weld the material SA 333 Gr.3 using the electrodes E6010 + E6018. Iany possibilities these electrodes acceptable to weld SA 333 Gr.3.
Regards,
DHINESH
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.