Even opened surface defects, when dirt not to be moved sufficient it can not use DPI.
Regards,
TRAN VAN VUONG
NDT Level III according to SNT-TC-1A
HP +84 912 262 085
Email: vuongtv@phateco.com
-------------------------------------------
PHATECO
Pha Rung Technical Services JSC.
Inspection Services
Add: 308 Van Cao Str., Haiphong City, Vietnam
Tel: +84 31 6 260 254
Fax: +84 31 3 559 448
Email:
Website: www.phateco.com
From:
Sent: Tuesday, June 29, 2010 11:35 PM
To:
Subject: Re: [MW:5794] MPI vs DPI
The major difference is the DPI is only for the defects that open to the surface and the MPI for the subsurface defect ( 6 mm deep). Eng.MOHAMMED ABD EL-AZIM HILAL MECHANICAL ENGINEER CSWIP 3.1 - NDT (RT- MT - PT) OTISHAN CONSULTANT ENGINEER 00966-502612218 - 0020103124557
Mpi can be used only on ferromagnetic materials |
--
To post to this group, send email to
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.