Monday, June 21, 2010

RE: [MW:5692] Welding Procedure

 

Sorry did mention that , its ASME  V Section I, Steam Generator Tubes Turn, I’m aware of test requirements Like mention below.

Its welding  P4& P5 and 410  Material to A-106, as per ASME, 2 ¼ cr PWHT is Optional but for  9 Cr is mandatory , What about welding 106 with 2 ¼ or 9 Cr with TIG root and E7018 cover pass and only carryout preheating to 300 F and eliminate PWHT.

Thanks,

 

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Harish Kannepalli
Sent: Saturday, June 19, 2010 5:41 AM
To: materials-welding@googlegroups.com
Subject: Re: [MW:5658] Welding Procedure

 

Dear Bhatti,
 What is code for Procedure? What is the job? Normally you require tensile,bend,charpy impact(conditional) and macroexamination.

2010/6/17 Bhatti BM (Bashir) at Aera <BMBhatti@aeraenergy.com>

 

 

 

Folks,

We doing  Mockup procedure before actual welding, what type tests are required to qualify the welding procedure

 

 I was looking for welding procedures for and filler metals

 CS A-106-B and 2 ¼ Cr ,

CS A-106-B and 410

CS A-106-B and 13 Cr

CS A-106-B and 9CR

 

Thanks , Bashbhat

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.




--
K Harish Kumar

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...