time delays required to source new fittings. if these are used in
lines which are categorised as normal fluid service, you may approch
your client with a devaition request and probably with additional NDT
on the longitudinal welds of these fititngs.
On Nov 10, 10:22 pm, carlos oliveros <carlosolive...@terra.com> wrote:
> BODY { font-family:Arial, Helvetica, sans-serif;font-size:12px; }
> Dears Friends.
>
> I work in a project Plant Compressor Gas under B31.3 The
> specification Project give the reference Fittings seamless and in
> Shop Fabrication the fitting are welded Elbow welded, Tee Welded. My
> question reject all fabrication or what is the solution.
>
> Thanks
> carlos oliveros
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---