Sunday, May 5, 2019

[MW:29560] UT Acceptance in AWS D 1.1 Class R

Dear All,

I received a UT report with 

Weld thickness= 16mm,

slag length = 11mm,

I followed the below figure for acceptance of the report, but I totally confused with Note a and Note b



Is this report (slag length) is acceptable as per the figure, please help me out.


Regards,

Arun Padman Manayil